Moisture Separator
Benefits: Lowest operating costs Highest efficiency Energy efficient Simple installation and maintenance Long life elements Reduced downtime Improved product quality Increased production output
Lowest operating costs
Highest efficiency
Energy efficient
Simple installation and maintenance
Long life elements
Reduced downtime
Improved product quality
Increased production output
MODEL
PIPE
SIZE
FLOW RATE
@7 bar g (102 psig)
DIMENSION (mm)
WEIGHT
cfm
m3/min
A
B
C
D
kg
MS 100
G ½
100
2.83
89
42
158
60
1.0
MS 150
G ¾
150
4.25
194
1.1
MS 185
G1
185
5.24
85
23
197
MS 365
G1 ½
365
10.34
120
58
251
80
2.7
MS 850
G2
850
24.07
160
67
511
5.9
MS 1700
G2 ½
1700
48.15
202
77
605
12.9
MS 2000
G3
2000
56.64
MS 2400
G4
2400
67.97
312
83
767
250
41
Engineering Data Maximum operating Pressure 16 bar g (232 psi g) Maximum recommended operating temperature 66ºC (150ºF) Minimum recommended operating temperature 1.5ºC (35ºF) Typical pressure differential at rated flow 20 — 60 m bar (0.3 — 0.9 psi) Line Pressure bar g 1 3 5 7 9 11 13 15 16 psi g 15 44 73 100 131 160 189 218 232 Correction Factor 0.5 0.71 0.87 1.0 1.12 1.22 1.32 1.41 1.56
Engineering Data
Maximum operating Pressure 16 bar g (232 psi g)
Maximum recommended operating temperature 66ºC (150ºF)
Minimum recommended operating temperature 1.5ºC (35ºF)
Typical pressure differential at rated flow 20 — 60 m bar (0.3 — 0.9 psi)
Line Pressure
bar g
1
3
5
7
9
11
13
15
16
psi g
44
73
131
189
218
232
Correction Factor
0.5
0.71
0.87
1.12
1.22
1.32
1.41
1.56